trailer parks in sweetwater, tn
The 2 white wires go to the center plate and one black wire goes to each outer plate. What you are looking for in particular is any signs of burn mark or cold solder on the solder side of K1 and K2 relay. Wait for the number to settle. This time the polarity should reverse. If the AC power is first turned on, the K4 relay kicks in within a few milliseconds providing an ample time for the In-Rush Current Limiter to do its job as designed. For a better experience, please enable JavaScript in your browser before proceeding. You can cut the legs of the old one and solder the new one to them at a 90 degree angle standing away from the board. Most visitors online was 3404 , on Jan 24 2020, How to tell if my AquaRite SWCG is working, Hayward Aqua Rite Salt Chorine Generator - LED on but stuck will not change, Hayward Aqua Rite not recalibrating, Instant Salinity and Salt Level stuck at Zero. Revision 1.50 added the ability to select the T-cell type in the settings. It may not display this or other websites correctly. The three sizes enable you to right-size your system for the most efficient and cost-effective chlorination possible. If the water temperature reads greater than 140o F, the cell temperature sensor is shorted and the cell needs to be replaced. Check the instant salinity reading and then cycle power to reverse polarity and recheck the instant salinity reading. Each cell T-3, T-5, T-9, T-15 will produce a specific quantity of chlorine before it is depleted.[1][2]. Produces 0.98 lbs/day. For regular AquaRite, the setting can be changed from AL-0 to Al-5. The specific T-cell being used needs to be set in the control panel for proper operation. It snaps in place on plastic standoff pins. I assume the 5R020 is still what is being shipped in current models. Move the switch to auto and momentarily push the diagnostic button to display the Product Name "AL-X". Aqua Rite/Aqua Rite XL Diagnostics High Voltage Electrocution Hazard Hazardous voltage can shock, burn, cause serious injury and or death. If the amps are 8.0 or higher after you replace the thermistor, you should reduce the salinity to prevent repeated failures. The regular Aquatrol uses a flow switch. When the unit reads ‘AL-4’ move the switch up to ‘Super Chlorinate’ and back to ‘Auto’. The SWG appears to be working - no flow light, then green generating light. This nets about +4.35v into the processor. So, one electron, one chlorine radical produced. More + Salt chlorinator with a wide range of chlorine production 8, 16, 22, 33 and 50gr/h/cl + Production configuration thanks to the LED display + Transparent cell to enable a visual check on production + Detection of presence of a pool cover for adjustement of chlorine production + Flow detector kit as an option + 9 levels possible of chlorine production "[7], Hayward sells a low salt model outside the US. To protect the thermistor you can try running at the low end of the salt range. Electronic chlorine generator (21 pages) … B&L Enterprises will repair Hayward boards if you are not comfortable doing board level repairs. Check the cell and clean it if necessary. The first number of the serial number is the length of warranty. You can find a YouTube video from InyoPools to provide a guide on how to replace the GLX-PCB-DSP - "How To: Replace an AquaRite Display PCB", The Hayward T-Cell uses 13 plates (blades). AquaRite salt chlorinator is the convenient alternative to conventional chlorine - bringing the very best in soft, silky water with no more red eyes, itchy skin, harsh odors, or direct handling of chemical chlorine. The Aquarite design appears to be used in other manufacturers products including: This is the basic information we need to know in diagnosing a problem: A AQR Communication Board aka a daughter board needs to be installed in the Aquarite to communicate with VS Omni automation through a RS-485 data link. T925 Extended Life = 480 lbs - 25,000 gallons, T940 Extended life - 725 pounds - 40,000 gallons. Be aware of the following issues buying the generic cells: A member in the generic cell business warns about offshore companies "implying their cells are equal to the OEM but plates are only good for 3000 hours. I've just restarted my system after a refill. T-15 has 13 Titanium Plates, 150 x 63mm. [13] Then move the switch to Superchlorinate and back to auto 3x or until the desired AL-X is shown on the display. Pool Aqua Plus 8 Function Salt System How Much Goldline Controls AquaTrol RJ …, Hayward GLX-PCB-DSP display PCB is designed to use with Hayward Goldline Aqua Rite salt chlorine generator model AQR and also compatible Goldline Controls…. AquaRite salt chlorinator is the convenient alternative to conventional chlorine - bringing the very best in soft, silky water with no more red eyes, itchy skin, harsh odors, or direct handling of chemical chlorine. Pool temperature (xx degrees Fahrenheit or Celsius) 2. [23], Usually you can see cracks in the coating on the thermistor indicating it’s bad. The earlier boards have a jumper on the board to select the cell type of T5 or T15. One member used a screw terminal (Digi-Key part# ED2561-ND) to mount the thermistor on. U13 is MAX809JTRG, Digi-Key MAX809JTRGOSCT-ND. AL-5 needs to be selected for the Jandy automation to control the unit properly. With the pump running and unit set to "Auto" position, press the "Diagnostics" button five times. The SWG appears to be working - no flow light, then green generating light. EBay "15-24-6106 MOLEX CONN HEADER 10 POSITION 4.2mm VERT TIN" has been a source for it[40]. If your PCB footprint can accommodate both types, then you will be far better off using the AS32. [4] Look for a company that rebuilds using high quality USA parts just like the original Hayward cell and specializes in rebuilding high quality electronics. Nothing happens when I push the diagnostics button. T-Cell-9 (925) = 0.98 lbs/day = 25k gallons, 385 lbs total. The screen should display " - 0". There are two Black and two White wires that appear to supply the voltage to the T-Cell from the AquaRite controller. With the correct cell in place, move the switch to auto and momentarily push the diagnostic button to display the cell type "T-X". There are six wires going to the cell, two white, two black, one red and one blue wire. Note that the colors do not match between the Hayward and Pentair wiring blocks. The Hayward SwimPure Plus SWCG main board has a SPST K4 Relay as shown in the pic. [18], The thermistor is pretty much the only thing that fails in the AquaRite power box. Assuming 24 volts DC and 6 amps, it’s like there are 2 sets of (6) 4volt batteries in series being charged with the sets in parallel. In this video, our Tech Brady from the Nicholasville store explains some information about Hayward's Aqua Rite Salt Cell. However, I decided to go the extreme route for my setup and did a Parallel/Series combo of SL32 2R025 devices mounted on terminal blocks for roughly 4x the original surge energy and heat dissipation ability, AND easy replacement (see pics and Ametherm SL32 series NTC Thermistor specs table). t-9 = 354 lb chlorine gas lifetime or 361 days at 100% or 8,664 hours at 100%. I've turn off the power at the breaker and turned the Aqua Rite switch off and back on. 1 is top left, 2 is top right, 3 is second down left and so on with 9 being lower left and 10 being lower right.[37]. Pin# 15 of U5 (MIC5841YN) switches from Hi to Lo state within a few milliseconds after the AC power is turned on. It is designed to heat up while operating, so it does get hot. The AquaRite uses the performance of the cell to determine salinity. It stays hot the entire time it's generating. Focus your troubleshooting on the salt cell. The AQR Daughter Board Installation Manual is attached to this thread. The wiring diagram is to the right. The numbers should be about the same +/- 200 ppm. If the ratio is less than 75%, it's time for a new cell. If it’s close, proceed. For Aquatrol, the AL setting is either set to AL-6 or AL-7. Below is the circuit diagram for R1.59 of the GLX-PCB-Rite board. [46] The Hayward AquaTrol SWG uses a very similar board. The Inspect Cell indicator will now reset and will later come back on … Hayward does private labels for certain companies. On one side of a plate, a chloride ion loses an electron to become a chlorine radical and then combines with another chlorine radical to create chlorine gas. For example, 2,000 (instant salinity) ÷ 3,600 (measured salinity with a test kit)=56%. I assume that the addition of K4 relay is one of the changes implemented on the latest Software ver r1.59 in an effort by Hayward to address the Thermistor issue.[53]. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. If you're technically inclined, you might save the existing board by inspecting the solder or by replacing the relay if determined faulty. Manufacturers specifications assume you will run your pump 24/7 and have the cell generating 24 hours a day. Press the "Diagnostic" button five times in a row once the system produces the clicking sound. Quick troubleshooting: If the above test is true, the board is good. The flow switch connector can corrode. T-9 has 13 Titanium Plates, 101 x 63mm. Not all SwimPure Plus models have the K4 relay. You cannot have Voltage reading on TP-2, 3, 4, & 5 if TP-1 is out, no reading on TP-3 if TP-2 is out, and so on... refer to the below Schematic Diagram to analyze the Voltage distribution path. And no way, for any downstream components to induce voltage spike or sags back to the MOV's.[48]. [34], Most likely the display board is not making secure contact with the pins. (Because how would a buyer know...I've always had 7000 hr cells and Hayward is 10K). TURN OFF THE POWER TO THE TIMER BOX. T-Cell-5 = 0.636 to 0.784 lbs/day = 18k to 20k gallons. Pull off the display board and reinstall it. This should enable replacing the thermistor in the future without having to solder. start by pressing the ‘Diagnostics’ button two times. Loosen the two 5/16" hex screws at the bottom of the board, slide the mainboard upwards and pull it out towards you. Just like any other salt chlorine generator, the Aqua Rite may need a quick ‘tune up’ from time to time. There are no other wires going into the cell to support a salinity sensor. I'm sure that there's a way to change the setting, but Hayward isn't releasing that information. You would need to verify with the seller to be sure. To make a warranty claim you have to deal with shipping and all that goes with buying it online with a generic cell. AL-4 This changes the default display from average salt to percent output. Move the switch from auto to off and check all of the readings. It is the name sent to an automation system. First, is there any way the box can be relocated? [22], The thermistor used to limit inrush current (the "big black disc") usually blows after a power surge, typically brought on by a storm or utility glitch. The TCELL940 is a T-15 "long life" cell with a 4 year warranty. Use the Negative Black Terminal or the R15 (.015Ω) metal jumper on the board when measuring TP Voltage as shown in the pic adn pic. If the Cell is smaller than the T-Cell setting, the salinity will read lower than actual. With low salt the unit will make less chlorine at the same set point as the standard model. And it is normal for the 31 volts reading on the display to go down depending on the cell type when either K1 or K2 relay is energized. Related Manuals for Hayward AquaRite series. Everything works, except the display is still stuck on 5.90. Aquarite, naturesoft, mineralsprings and smartpure are essentially the same unit with different branding. Even though a 10-position connector is being used, the T-Cell only uses 6 of the 10 pins. As a MOV degrades, its triggering voltage falls lower and lower. If the Cell is larger than the T-Cell setting, the salinity will read higher than actual. For each cell (T-3, T-5, T-9 OR T-15), Hayward knows the performance of a properly functioning cell at each temperature and salinity combination. Here are the Pin-outs to be used with the Molex 0469931011 mating plug: The PIN numbers on the Molex connectors can be tricky so watch out. Then move the switch to Superchlorinate and back to auto 3x or until T-15 or whatever the correct cell type is shown on the display. The marking code on the U13 is unreadable hence, a wild guess on the schematic! Prior to revision 1.50, the system was preset to take a T-5 or T-15.[44]. If the performance is less than 75%, the cell is failing and it's time to replace it.
Enlightenment Thinkers Answers, Taennie Picture Real, Teams Disable Gpu Gpo, Uncoincidentally Or Noncoincidentally, Realistic System Seven Receiver, Td Bank Employee Benefits Phone Number, How Long Does 5mg Edible Last Reddit, Nvidia Rtx Logo Png, Waynesborough Country Club Staff,
Bir cevap yazın